Standards governing the design, fabrication, and installation of HVAC duct systems include those of the following organizations:
I. North American Insulation Manufacturers Association (NAIMA)
a. Fibrous Glass Duct Construction Standard, Fifth Edition, 2002, Publication AH 116
This Standard contains recommended methods of fabricating and installing air handing ducts using fibrous glass duct board material as defined herein. It covers duct board performance criteria, assembly, fabrication, fittings, approved closures, reinforcement, hanging, support and damage repair. This standard was developed using reliable engineering principles and research, plus information obtained from manufacturers, contractors, testing laboratories, and others with specialized experience. A 3-part CSI Masterformat ® specification is included.
b. Fibrous Glass Residential Duct Construction Standard, Third Edition, 2001, Publication AH 119
This Standard is based on the Fibrous Glass Duct Construction Standard cited above, but focuses on recommended methods of fabricating and installing air handling ducts in residential and light commercial structures. A 3-part CSI Masterformat R specification is included.
c. Fibrous Glass Duct Liner Standard, Third Edition, 2002, Publication AH 124
This standard sets forth important properties of fibrous glass duct liner materials, acoustical and thermal performance, contribution to indoor environmental quality, and installation procedures. A 3-part CSI Masterformat R specification is included.
II. Sheet Metal and Air Conditioning Contractors National Association (SMACNA)
a. Fibrous Glass Duct Construction Standards, Seventh Edition, 2003
This standard served as a basis for the scope and content of the above cited NAIMA standard.
b. HVAC Duct Construction Standards, Second Edition, 1995
This standard includes sections on installation of fibrous glass duct liner materials and insulated flexible duct systems.
III. Air Diffusion Council (ADC)
a. Flexible Duct Performance and Installation Standards, Fourth Edition, 2003
This standard sets forth specific methods of classifying, testing, marking, and installing flexible ducts in air distribution systems. It references ADC Test Code FD- 72R1, which establishes values and procedures for testing insulated flexible ducts in terms of air friction loss, acoustical performance, static pressure/ temperature performance, and leakage. Fabrication and installation guidelines are included.
IV. Midwest Insulation Contractors Association (MICA)
a. National Commercial and Industrial Insulation Standards, Fifth Edition, 1999
This standard includes installation and fabrication specifications for fibrous glass duct wrap and duct liner, as well as for rigid fibrous glass exterior board insulation over metal ducts.