9.27.8. Plywood

9.27.8. Plywood
9.27.8.1. Material Standards
  1. Plywood cladding shall be exterior type conforming to
    1. ANSI/HPVA HP-1, "Hardwood and Decorative Plywood,"
    2. CSA O121, "Douglas Fir Plywood,"
    3. CSA O151, "Canadian Softwood Plywood," or
    4. CSA O153, "Poplar Plywood."
9.27.8.2. Thickness
  1. Plywood cladding shall be not less than 6 mm thick when applied directly to sheathing.
  2. When applied directly to framing or over furring strips, plywood cladding thickness shall conform to Table 9.27.8.2.

    Table 9.27.8.2.
    Minimum Plywood Cladding Thickness

    Forming Part of Sentence 9.27.8.2.(2)


  3. The thickness of grooved or textured plywood cladding shall be measured at the point of least thickness.
9.27.8.3. Edge Treatment
  1. The edges of plywood cladding shall be treated with a suitable paint or sealer.
9.27.8.4. Panel Cladding
  1. Plywood applied in panels shall have all edges supported.
  2. Not less than a 2 mm gap shall be provided between panels referred to in Sentence (1).
  3. Vertical joints in cladding referred to in Sentence (1) shall be protected with batten strips or sealant when the plywood joints are not matched.
  4. Horizontal joints in cladding referred to in Sentence (1) shall be lapped not less than 25 mm or shall be suitably flashed.
9.27.8.5. Lapped Strip Siding
  1. Plywood applied in horizontal lapped strips shall have not less than a 2 mm gap provided at the butted ends, which shall be caulked.
  2. The horizontal joints of siding described in Sentence (1) shall be lapped not less than 25 mm.
  3. Wedges shall be inserted under all vertical butt joints and at all corners when horizontal lapped plywood is applied without sheathing.