Backdraft Indicators

----------

NOTES

Indicators of possible backdraft:

  • Pulsating smoke "building breathing";
  • Closed windows and doors with yellowish-grey smoke seeping out then drawing in;
  • Lack of visible flames - doors and windows hot - discoloured window glass - windows cracked from heat;
  • Possible whistling sound around doors and windows;
  • Pulsating raising and lowering of smoke layer inside.