9.25.2.2.(1) Except as required in Sentence (2), thermal insulation shall conform to the requirements of:
a) ASTM C 726, "Mineral Wool Roof Insulation Board,"
b) CAN/CGSB-51.25-M, "Thermal Insulation, Phenolic, Faced,"
c) CGSB 51-GP-27M, "Thermal Insulation, Polystyrene, Loose Fill,"
d) CAN/ULC-S701, "Thermal Insulation, Polystyrene, Boards and Pipe Covering,"
e) CAN/ULC-S702, "Mineral Fibre Thermal Insulation for Buildings,"
f) CAN/ULC-S703, "Cellulose Fibre Insulation for Buildings,"
g) CAN/ULC-S704, Thermal Insulation, Polyurethane and Polyisocyanurate, Boards, Faced,"
h) CAN/ULC-S705.1, "Thermal Insulation - Spray Applied Rigid Polyurethane Foam, Medium Density - Material - Specification," or
i) CAN/ULC-S706, "Wood Fibre Insulating Boards for Buildings."
9.25.2.2.(2) The flame-spread ratings requirements contained in the standards listed in Sentence (1) shall not apply.