5.9.1.1. |
Compliance with Applicable Standards
- Except as provided in Sentence (2) and elsewhere in this Part, materials and components, and their installation, shall conform to the requirements of the applicable standards in Table 5.9.1.1. where those materials or components are
- incorporated into environmental separators or assemblies exposed to the exterior, and
- installed to fulfill the requirements of this Part.
(See Note A-5.9.1.1.(1).)
- The requirements for flame-spread ratings contained in thermal insulation standards shall be applied only as required in Part 3.
Table 5.9.1.1.
Standards Applicable to Environmental Separators and Assemblies Exposed to the Exterior
Forming Part of Sentence 5.9.1.1.(1)
Notes to Table 5.9.1.1.:
(1) See Note A-Table 5.9.1.1.
(2) The flame-spread rating of gypsum board shall be determined in accordance with CAN/ULC-S102 in lieu of ASTM E 84 as indicated in ASTM C 1396/C 1396M.
(3) The flame-spread rating of glass mat gypsum panels shall be determined in accordance with CAN/ULC-S102 in lieu of ASTM E 84 as indicated in ASTM C 1658/C 1658M.
(4) For the purpose of compliance with Part 5, ASTM D 3019 shall only apply to the non-fibered and non-asbestos-fibered types of asphalt roll roofing.
|