9.14.6. Surface Drainage

9.14.6. Surface Drainage
9.14.6.1. Surface Drainage
  1. The building shall be located or the building site graded so that water will not accumulate at or near the building.
9.14.6.2. Drainage away from Wells or Septic Disposal Beds
  1. Surface drainage shall be directed away from the location of a water supply well or septic tank disposal bed.
9.14.6.3. Window Wells
  1. Every window well shall be drained to the footing level or other suitable location.
9.14.6.4. Catch Basin
  1. Where runoff water from a driveway is likely to accumulate or enter a garage, a catch basin shall be installed to provide adequate drainage.
9.14.6.5. Downspouts
  1. Downspouts shall conform to Article 9.26.18.2.