9.14.6. |
Surface Drainage |
9.14.6.1. |
Surface Drainage
- The building shall be located or the building site graded so that water will not accumulate at or near the building.
|
9.14.6.2. |
Drainage away from Wells or Septic Disposal Beds
- Surface drainage shall be directed away from the location of a water supply well or septic tank disposal bed.
|
9.14.6.3. |
Window Wells
- Every window well shall be drained to the footing level or other suitable location.
|
9.14.6.4. |
Catch Basin
- Where runoff water from a driveway is likely to accumulate or enter a garage, a catch basin shall be installed to provide adequate drainage.
|
9.14.6.5. |
Downspouts
- Downspouts shall conform to Article 9.26.18.2.
|