9.33.5. |
Heating and Air-conditioning Appliances and Equipment |
9.33.5.1. |
Capacity of Heating Appliances
- The required capacity of heating appliances located in a dwelling unit and serving only that dwelling unit, shall be determined in accordance with CSA F280, "Determining the Required Capacity of Residential Space Heating and Cooling Appliances," except that the design temperatures shall conform to Subsection 9.33.3.
|
9.33.5.2. |
Installation Standards
- Except as provided in Articles 9.33.5.3. and 9.33.5.4., the installation of heating and air-conditioning equipment, including mechanical refrigeration equipment, and including provisions for mounting, clearances and air supply, shall conform to applicable provincial or territorial regulations or municipal bylaws or, in the absence of such regulations or bylaws, to
- CSA B51, "Boiler, Pressure Vessel, and Pressure Piping Code,"
- CSA B52, "Mechanical Refrigeration Code,"
- CSA B139, "Installation Code for Oil-Burning Equipment,"
- CSA B149.1, "Natural Gas and Propane Installation Code,"
- CSA C22.1, "Canadian Electrical Code, Part I," or
- CSA C448 Series, "Design and Installation of Earth Energy Systems." (See also Sentence 9.33.5.3.(1).)
|
9.33.5.3. |
Design, Construction and Installation Standard for Solid-Fuel-Burning Appliances (See Note A-9.33.5.3.)
- The design, construction and installation, including the provision of combustion air, of solid-fuel-burning appliances and equipment, including stoves, cooktops, ovens and space heaters, shall conform to CSA B365, "Installation Code for Solid-Fuel-Burning Appliances and Equipment."
|
9.33.5.4. |
Fireplaces
- Fireplaces shall conform to Section 9.22.
|