An exterior lighting outlet with fixture controlled by a wall switch located within the building shall be provided at every entrance to buildings of residential occupancy.
9.34.2.2.
Outlets in Dwelling Units
Except as provided in Sentence (2), a lighting outlet with fixture controlled by a wall switch shall be provided in kitchens, bedrooms, living rooms, utility rooms, laundry rooms, dining rooms, bathrooms, water-closet rooms, vestibules and hallways in dwelling units.
Where a receptacle controlled by a wall switch is provided in bedrooms or living rooms, such rooms need not conform to the requirements in Sentence (1).
9.34.2.3.
Stairways
Every stairway shall be lighted.
Except as provided in Sentence (3), 3-way wall switches located at the head and foot of every stairway shall be provided to control at least one lighting outlet with fixture for stairways with 4 or more risers in dwelling units and houses with a secondary suite including their common spaces.
The stairway lighting for basements that do not contain finished space or lead to an outside entrance or built-in garage and which serve not more than one dwelling unit is permitted to be controlled by a single switch located at the head of the stairs.
9.34.2.4.
Basements
A lighting outlet with fixture shall be provided for each 30 m2 or fraction thereof of floor area in unfinished basements.
The outlet required in Sentence (1) nearest the stairs shall be controlled by a wall switch located at the head of the stairs.
9.34.2.5.
Storage Rooms
A lighting outlet with fixture shall be provided in storage rooms.
9.34.2.6.
Garages and Carports
A lighting outlet with fixture shall be provided for an attached, built-in or detached garage or carport.
Except as provided in Sentence (3), outlets required in Sentence (1) shall be controlled by a wall switch near the doorway.
Where the outlet and fixture required in Sentence (1) are ceiling mounted above an area not normally occupied by a parked car, or are wall mounted, a fixture with a built-in switch accessible to an adult of average height is permitted to be used.
Where a carport is lighted by a light at the entrance to a dwelling unit, additional carport lighting is not required.
9.34.2.7.
Public and Service Areas
Every public or service area in buildings shall be provided with lighting outlets with fixtures controlled by a wall switch or panel to illuminate every portion of such areas.
When provided by incandescent lighting, illumination required in Sentence (1) shall conform to Table 9.34.2.7. (See Article 9.9.12.2. for lighting in means of egress.)
When other types of lighting are used, illumination equivalent to that shown in Table 9.34.2.7. shall be provided.
Table 9.34.2.7.
Lighting for Public Areas
Forming Part of Sentences 9.34.2.7.(2) and (3)